Rotary Switches
 
General
RECOM range of Rotary Switches incorporate wiping contact design concept to meet reliable standards for arduous industrial applications. These are basically designed for manual operation and essentially recommended for ON-LOAD switching of resistive and inductive circuits. This design permits infinite combination of circuits, variety of attachments and accessories to meet any standard & non-standard specification. RECOM Rotary Switches are widely used for isolation, selection, control and auxiliary switching, in Control Panels, Switch Boards, Cubicles, Control Desks Motor Control Centres, Mechine Tools, electrical equipments etc.

Construction :
Based on packet principle, switches incorporate air-break type wiping contacts operating on rotary action thus making and breaking the required circuit between fixed and moving contacts, manufactured out of specially selected contact materials and housed in anti-tracking quality moulded packets. Moving Contacts are operated through an insulated spindle by means of a positive indexing mechanism, while Fixed Contacts are positioned in the packets. This complete assembly of Contacts and Mechanism is manually rotated with suitable handle.

Mechanism
Rotary Switches are manufactured with 2 Two Types of Mechanisms
  • Quick Make / Slow Break action for AC circuits
  • Quick Make / Quick Break action for DC circuits which is independent of the action of the operator.
Specification
RECOM Rotary Switches comply with IS 13947 (Pt 3): 1993 utln. cat. AC-22A ISS 4064 Pt. 1-1978, IEC 408 & Defence Specification JSS 51208,

Test
Each switch is tested to withstand H. V. test of 2.5 KV for one minute.

Temperature
Switches are recommended to be used under temperatures upto 50° C Ambient.

Guarantee
Each RECOM Switch carries with it a guarantee against manufacturing defects and faulty workmanship for a period of 12 months from the date of purchase.
 
Range Standard (Non-standard Applications on request)
Mounting Panel (Flush at the back)
Switching 90° 4 Positions
Current 16 Amperes AC
Voltages 250 for Single phase 1  & 2 Poles
  440 for Three phase   3 Poles & above
Frequency 50 Hz
 
     
Switching Sequence Indicating Plates Switching Positions Circuit Schematics
Single Pole
No. of Poles Switch Code Length
in mm
OFF - ON 1 PA 2116 38
  2 PA 3216 44
  3 PA 4316 70
4-POSITION 4 PA 5416 78
 
2 WAY 1 PA 3116A 44
NO OFF 2 PA 5216A 56
  3 PA 7316A 94
A 4 PA 9416A 110

2 WAY 1 PA 3116B 44
+ OFF 2 PA 5216B 56
B 3 PA 7316B 94
4-POSITION 4 PA 9416B 110
 
3 WAY 1 PA 3116C 44
+ OFF 2 PA 6216C 62
C 3 PA 9316C 110
4-POSITION 4 PA 12416C 134
 
4 WAY 1 PA 3116D 44
NO OFF 2 PA 6216D 62
D 3 PA 9316D 110
4-POSITION 4 PA 12416D 134
 
Range Standard (Non-standard Application on request)
Mounting Panel (Flush at the back)
Switching 90° 4 Positions
Current 10 Amperes or
  (16 Amps AC at 2 50V for Single Phase)
Voltages 440 for Three phase 3 Poles & above
Frequency 50 Hz
 
 
Switching Sequence Indicating Plates Switching Positions Circuit Schematics
Single Pole
No. of Poles Switch Code Length
in mm
OFF-ON      
  3 PA 4310 50
  4 PA 5410 56
4-POSITION      
 
2 WAY      
NO OFF 3 PA 7310A 68
  4 PA 9410A 80
A      

2 WAY      
+ OFF 3 PA 7310B 68
B 4 PA 9410B 80
4-POSITION      
 
3 WAY      
+ OFF 3 PA 9310C

68

C 4 PA 12410C

98

4-POSITION      
 
4 WAY      
NO OFF 3 PA 931OD

80

D 4 PA12410D 98
4-POSITION      
 
Switches for Surface Mounting (Base Panel) available on request.
 

Range

Standard (Non-standard Application on request)

Mounting

Panel (Flush at the back)

Switching

90° 4 Positions

Current

10 Amperes AC

Voltages

440 for Three phase 3 Poles & above

Frequency

50 Hz

 

Switching Sequence

Indicating Plates

Circuit Schematics

Switch Code

Length in mm.

Ammeter Selector
To read Current, through CT's, in each Phase + OFF. 4-Position

PA 6310 AM 62
Ammeter Selector
To read Current, through CT's (Delta connected), in each Phase + OFF. 4-Position

PA10310 AM 86
Ammeter Selector
To read Current directly (Without CTs) in each Phase + OFF. 4-Position

PA 11310 AM 92
Voltmeter Selector

To read Voltage between Phases + OFF. 4-Position

PA 5310 VM 56
Voltmeter Selector
To read Voltage between each Phase and Neutral + OFF. 4-Position

PA 5110 VM 56
 

NOTE : CT's are shorted between positions by Make-Before-Break Contacts to avoid risks of open circuit conditions.

 
Range Standard (Non-standard Application on request)
Mounting Panel (Flush at the back)
Switching 90° 4 Positions
Current 25 Amperes AC
  250 for Single phase   1  & 2 Poles
Voltages 440 for Three phase    3 Poles & above
Frequency 50 Hz
 
 
Switching Sequence Indicating Plates Switching Positions Circuit Schematics
Single Pole
No. of Poles Switch Code Length
in mm
OFF - ON 1 PA 3125 44
  2 PA 5225 56
  3 PA 7325 94
4-POSITION 4 PA 9425 110
 
2 WAY 1 PA 3125A 44
NO OFF 2 PA 5225A 56
  3 PA 7325A 94
A 4 PA 9425A 110

2 WAY 1 PA 5125B 56
+ OFF 2 PA 9225B 80
B 3 PA13325B 142
4-POSITION 4 -  
 
3 WAY 1 PA 5125B 56
+ OFF 2 PA 9225B 80
C 3 PA13325B 142
4-POSITION 4 -  
 
4 WAY 1 PA 5125B 56
NO OFF 2 PA 9225B 80
D 3 PA13325B 142
4-POSITION 4 -  
 
Range Standard (Non-standard Application on request)
Mounting Panel (Flush at the back)
Switching 90° 4 Positions
Current 40 Amperes AC
Voltages 250 for Single phase   1  & 2 Poles
  440 for Three phase    3 Poles & above
Frequency 50 Hz
 
 
Switching Sequence Indicating Plates Switching Positions Circuit Schematics
Single Pole
No. of Poles Switch Code Length
in mm
OFF - ON 1 PA 2140 53
  2 PA 3240 63
  3 PA 4340 74
4-POSITION 4 PA 5440 84
 
2 WAY 1 PA3140A 63
NO OFF 2 PA 5240 A 84
  3 PA 7340 A 104
A 4 PA 9440 A 125

2 WAY 1 PA3140B 63
+ OFF 2 PA 5240 B 84
B 3 PA 7340 B 104
4-POSITION 4 PA 9440B 125
 
3 WAY 1 PA 3140C 63
+ OFF 2 PA 6240C 94
C 3 PA 9340C 125
4-POSITION 4 PA 12440C 155
 
4 WAY 1 PA 3140D 63
NO OFF 2 PA 6240D 94
D 3 PA 9340D 125
4-POSITION 4 PA 12440D 155
 
Range Standard (Non-standard Application on request)
Mounting Panel (Flush at the back)
Switching 90°  4 Positions
Current 63 Amperes AC
  250 for Single phase 1 & 2 Poles
Voltages 440 for Three phase 3 Poles & above
Frequency 50 Hz
 
 
Switching Sequence Indicating Plates Switching Positions Circuit Schematics
Single Pole
No. of Poles Switch Code Length
in mm
OFF - ON 1 PA 3163 63
  2 PA 5263 84
  3 PA 7363 104
4-POSITION 4 PA 9463 125
 
2 WAY 1 PA3163A 63
NO OFF 2 PA 5263A 84
  3 PA 7363A 104
A 4 PA 9463A 125

2 WAY 1 PA5163B 84
+ OFF 2 PA 9263B 125
B 3 PA 13363B 166
4-POSITION 4 PA 17463B 207
 
3 WAY 1 PA5163B 84
+ OFF 2 PA 9263B 125
C 3 PA 13363B 166
4-POSITION 4 PA 17463B 207
 
4 WAY 1 PA5163B 84
NO OFF 2 PA 9263B 125
D 3 PA 13363B 166
4-POSITION 4 PA 17463B 207
 
Switches for Surface Mounting (Base Panel) available on request.
 
 
 
© Copyright 2007, Recom Pvt. Ltd. All rights reserved. Designed & Maintained by : Dhruv Infotech